INSTALLING THE CHIME MODULE
Install the optional chime module MC3 or MC8 in the wall
housing by pressing the chime module over the four plastic
standoffs attached to the wall housing as shown in Figure 12.
The DMC3-4 supports the 3-note Model MC3 and 8-note
Model MC8 chime modules. The chime module installs
inside the wall housing and is activated by the Door Station
pushbutton.
1. Install the chime module circuit board by snapping it onto the four
plastic mounting standoffs in the wall housing.
2. Refer to the instructions shipped with the chime module.
OPTIONAL DOOR RELEASE RELAY
The DMC3-4 Master Station contains a dry contact relay that
can be used to control external devices. Typical applications
include activating a door strike, triggering a panic alarm
system, or controlling a home automation or lighting system.
The door release relay has normally open contacts that
are rated at 2 Amps @ 24 Volts AC/DC. The relay can be
activated from the DMC3-4 Master Station or remote scan
Room Stations (Model DMC3RS or DMC4RS) by pressing
the volume up and volume down buttons together for four
seconds. The relay will deactivate when the buttons are
released.
Refer to the following steps for connecting a Model DRW
Door Release Mechanism (see Figure 13). For controlling
other devices, refer to the hook-up instructions supplied
with the device.
1. Route 2-conductor 18 AWG cable from the DMC3-4 Master Station’s
wall housing to the door release location.
2. Route 2-conductor 18 AWG cable from the DMC3-4 Master Station’s
wall housing to a location for a Model RT11 Remote Transformer. The
transformer plugs into a standard 120 VAC outlet.
3. Route the two cables into the Master Station’s wall housing through
the top left wiring access hole or slot. Leave about 12” of extra cable
extending at the wall housing.
4. Zip-tie the two cables together and LABEL THE CABLES “Door
Release”.
5. Use a wire nut to connect one wire from the transformer cable to one
wire from the door strike.
CHIME MODULE
MOUNTS ON FOUR
STANDOFFS INSIDE
THE DMC1H OR DMC1HC
WALL HOUSING
MC3 OR MC8
CHIME MODULE
Figure 12. Chime Module Installation
MODEL RT11
PLUG-IN
TRANSFORMER
2-CONDUCTOR
18 AWG
CABLE
MODEL DRW
ELECTRIC
DOOR STRIKE
WIRE
NUT
TO DMC3-4
MASTER STATION
DOOR RELEASE
TERMINALS
Figure 13. Door Release Wiring